Customer-owned data centre
WinCenter, compute, virtual networking and storage can be deployed in the customer environment without moving workloads to a public cloud.
CNware Reseller · VMware alternative · On-Prem infrastructure
GNS Technology Limited is a CNware reseller covering product sales, quotations and licensing coordination. Where required, GNS also delivers VMware discovery, PoC, architecture, migration, deployment, testing, acceptance and after-sales support. The platform can be deployed in the customer's data centre or an isolated network, making it a priority option to assess for government, banking and organisations that require data to remain on-prem.
GNS, CNware and on-prem delivery responsibilities
GNS works with CNware (Winhong) as a reseller and can deliver the Hong Kong implementation. CNware product and brand rights remain with their owner. GNS provides sales, quotations, licensing coordination, requirements, PoC, solution design, migration, deployment, testing, acceptance and after-sales support. Product versions, features, compatibility, certifications, licensing and vendor support remain subject to current documentation and the formal contract.
On-Prem first
CNware can be deployed in the customer's own data centre, private cloud or isolated network according to policy. Connectivity, licence activation, updates and support arrangements are defined per project.
WinCenter, compute, virtual networking and storage can be deployed in the customer environment without moving workloads to a public cloud.
Design around segmentation, VLAN, VPC, security groups, audit and management-network separation required by government or financial institutions.
A priority option where local control, private cloud, HA/DR and supply-chain diversity matter; compliance still depends on version, certification and procurement terms.
WinSphere supports traditional virtualisation clusters; WinStack combines compute, WinStore storage and WinFabric SDN.
Design local high availability, same-site or remote DR, VM backup, CDP and rollback to reduce dependence on external cloud services.
GNS can provide PoC, deployment, runbooks, testing, knowledge transfer, on-site support and optional 24/7 managed service.
The vendor positions WinSphere as a same-position VMware vSphere replacement, with a similar configuration style. A real project still needs a line-by-line comparison of VMware features, versions, APIs, backup, networking, storage, GPU and third-party ecosystem dependencies.
| Common VMware component | CNware direction | What the project must verify |
|---|---|---|
| vSphere/ESXi | WinSphere/KVM-based WinServer | VM hardware, Guest OS, CPU features, GPU and host profiles |
| vCenter | WinCenter management | Permissions, SSO, APIs, alerts, reporting and automation |
| vSAN | WinStore distributed storage | Replicas/EC, performance, rebuild, protocols and capacity |
| NSX | WinFabric SDN | VPC, micro-segmentation, firewall, VPN, LB, NAT and physical-network integration |
| vMotion/Storage vMotion | CNware live/storage migration | Cross-host, cross-cluster, cross-site and encrypted migration |
| Site Recovery Manager/backup | Built-in backup, DR, CDP and third-party options | RPO/RTO, agentless/agent, drills and failback |
| HCX | WinCMM, V2C and X2C | VMware Tools, snapshots, SR-IOV, independent disks and cutover |
Important: this is a high-level mapping, not a guarantee that every VMware edition, plug-in, API or ecosystem feature is equivalent. Use the current compatibility matrix and a PoC as the replacement evidence.
On-Prem reference architecture
WinCenter/WinSphere provides cluster, VM, permission, monitoring and reporting management. WinSphere/WinServer handles VMs, containers, GPU and HA. WinFabric provides VPC, SDN and micro-segmentation. WinStore provides block, file and object storage. WinCMM handles VMware, physical-server and third-party platform migration.
The platform can run across x86, ARM and a range of domestic CPU/OS environments. The diagram is a high-level assessment reference; actual components, versions, sizing and network connectivity must follow vendor documentation and project PoC evidence.
Government and banking
These are technical and deployment alignment points, not an automatic claim of compliance with any regulator, certification scheme or public-sector procurement requirement.
Management, compute, storage and business VMs can remain in the customer data centre where core workloads cannot move to public cloud.
Vendor material lists 2FA, three-member administration, role permissions, log audit, system activity records and third-party identity integration.
Design HA, DRS/DPM, same-site or remote DR, automated drills, failover and failback against agreed RTO/RPO.
WinFabric supports VPC, security groups, micro-segmentation and distributed firewalls for departments, tenants and sensitive systems.
The vendor overview covers x86, ARM, Hygon, Kunpeng, Phytium and Loongson for mixed or domestic compute pools.
Use PoC, migration waves, validation and rollback instead of attempting a single cutover of the entire VMware estate.
VMware migration
Inventory vCenter/ESXi versions, VM count, Guest OS, vCPU/RAM/disk, VMware Tools, hardware version, snapshots, SR-IOV, independent disks and business dependencies.
Select WinSphere or WinStack and design compute, WinStore, WinFabric, HA, backup, DR, networking, security and capacity.
Assess agentless V2C for compatible VMware workloads; use agent plus CDP in X2C for other platforms or special workloads, measuring downtime, throughput and success rate.
Plan business-priority waves, parallel running, final incremental sync, application switching and rollback windows instead of one uncontrolled cutover.
Validate boot, applications, networking, permissions, performance, backup and monitoring, retaining the source VM until acceptance.
Deliver architecture, compatibility reports, test evidence, operating procedures, alerts, backup/DR runbooks and knowledge transfer.
FAQ
GNS works with CNware (Winhong) as a reseller for sales, quotations and licensing coordination. Where required, GNS also delivers Hong Kong VMware discovery, PoC, architecture, migration, deployment, testing, acceptance and after-sales support.
The vendor positions WinSphere as a same-position VMware vSphere alternative, supported by WinCenter, WinStore, WinFabric and VMware migration tools. Full or partial replacement depends on VMs, Guest OS, GPU, backup, APIs, networking, storage, third-party tools, licensing and PoC results; the product name alone is not enough.
It can be deployed in the customer's data centre, private cloud or isolated network according to policy. Internet connectivity, licence activation, updates, remote support and third-party services must be defined in the design and contract.
CNware is a candidate to assess for on-prem virtualization, private cloud, domestic technology, VMware replacement and DR. Compliance with a specific institution still requires proof of version, certifications, cryptography, audit, vulnerability handling, SLA, procurement and vendor support.
WinSphere suits virtualisation pools built on existing servers and SAN/NAS or independent storage. WinStack combines WinSphere, distributed WinStore storage and WinFabric SDN into an HCI architecture, typically for new private clouds, branches or integrated compute/storage/network projects.
Vendor material provides agentless V2C live/cold migration and agent-based X2C with CDP. Low downtime is not zero downtime: full and incremental sync, cutover, application validation and rollback rehearsal are still required, and complex VMs may require a short outage or remediation.
The overview lists VMware Tools installed, hardware version 7 or later, no disk mounted in a CD-ROM, no SR-IOV, no snapshot and no independent persistent or nonpersistent disks. Network access to vCenter 443 and ESXi 902 is also required.
The vendor overview lists x86, ARM, Hygon, Kunpeng, Phytium and Loongson, with mixed deployment, unified images, monitoring and same-architecture cross-chip migration. The exact versions, migration directions and support matrix must be confirmed by the vendor.
No. GNS can provide reseller quotations and licence coordination only, or deliver VMware discovery, compatibility assessment, PoC, architecture, network and storage design, migration, deployment, HA/DR, testing, acceptance, training and after-sales support.
Provide VMware vCenter/ESXi versions, VM count, CPU/RAM/storage, Guest OS, HA/DR requirements, whether WinFabric/WinStore are required, hardware brands and compute architectures. GNS will structure licence and implementation pricing by edition, nodes, features, vendor support and engineering scope.
For VMware assessment, private cloud and heterogeneous-compute architecture, pair CNware with Network Infrastructure Design & Implementation, API Development & Integration and 24/7 Managed Support.
GNS is also part of the SI Partner Programme and can act as a CNware reseller for procurement, licensing coordination and local implementation.
Last updated: 16 November 2026. Information is based on the 2026 CNware Product Introduction. Actual features, versions, certifications, licensing and support follow current vendor documentation and the contract.
Send VM count, VMware versions, existing hardware, networking/storage, HA/DR, compliance and application inventory. GNS can first assess compatibility and TCO, then structure licence pricing and a migration PoC.